HP DL380 G3

By donmc, 3 April, 2008
Topic
contents
 Overview      Standard Features      Models      Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Overview

HP ProLiant DL380 Generation 3 (G3)

 
1.
24X Max CD-ROM (with easy front ejection removal)
2.
Front LEDs (show server status)
3.
Unit Identification button and LED
(for easy in rack server identification)
4.
1.44 MB Diskette Drive
5.
Six 1" Wide Ultra3/Ultra320 SCSI hot plug hard drives and one DAT 40 or DAT 72 hot plug tape drive
6.
2U form factor
 
What's New
The ProLiant DL380 G3 is now available with two new high performance processors:
  • The 3.2GHz Intel Xeon processor with 2MB of Level 3 cache delivering top performance for the most demanding applications
  • The 2.8GHz Intel Xeon processors with1MB of Level 3 cache offering a significant performance increase over the 3.06GHz/512MB processor at a price point that won't break your budget.

At A Glance

  • Integrated Lights-Out (iLO) Management standard on system board
  • Five Peer PCI Architecture up to 3.2 GHz processors and a 533MHz Front Side Bus
  • ServerWorks GC -LE Chipset
  • Integrated Smart Array 5i Plus Controller with optional Battery-Backed Write Cache (BBWC) Enabler option kit
  • Three available 64-bit PCI-X slots, including two hot pluggable 100MHz slots and one 133MHz slot
  • Two NC7781 PCI-X Gigabit NICs (embedded)
  • Support for up to six 1" Wide Ultra3/Ultra320 SCSI hot plug hard drives or for five hot plug hard drives and one AIT hot plug tape drive
  • User configurable single/dual channel drive backplane
  • Internal hot plug capacity 1.80 TB standard (6 x 300 GB 1" U320 HD)
  • 400-Watt Hot Plug Power Supply (with optional redundancy)
  • Hot Pluggable Fans (with optional redundancy)
  • Sliding rails and cable management arm for easy serviceability and in-rack tool-less access to major components
  • Automatic Server Recovery (ASR), ROM Based Setup Utility (RBSU), Insight Manager 7, Status LEDs including system health and UID and SmartStart
  • Protected by HP Services, including a three-year, Next Business Day, on-site limited Global warranty and extended Pre-Failure Warranty, which covers processors, memory, and hard drives - Certain restrictions and exclusions apply. Consult the HP Customer Support Center at 1-800-345-1518 for details.
  • Microsoft® Windows® 2000 Model
contents
 Overview      Standard Features      Models      Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Standard Features

Processor
One of the following depending on Model:
Intel Xeon Processor 3.2 GHz/533MHz - 512KB/2MB
Intel Xeon Processor 3.2 GHz/533 MHz - 512KB/1MB
Intel Xeon Processor 3.06 GHz/533 MHz - 512KB/1MB
Intel Xeon Processor 2.8 GHz/533MHz - 512KB/1MB
Intel Xeon Processor 3.06 GHz/533MHz - 512KB
Intel Xeon Processor 2.8 GHz/400MHz - 512KB
Intel Xeon Processor 2.4 GHz/400MHz - 512KB

Cache Memory
One of the following depending on Model:
2-MB Level 3 cache
(NOTE: Included with some 3.2 GHz models.)
1-MB Level 3 cache
(NOTE: Included with some 2.8 GHz, 3.2 GHz or 3.06 GHz models.)
  512-KB Level 2 cache
(NOTE: Included with all models.)

Upgradability Upgradable to dual processing

ChipsetServerWorks GC -LE Chipset
 NOTE: For more information regarding ServerWorks, please see the following URL:
http://www.serverworks.com/products/overview.html.

Memory

Standard 1GB of 2-way interleaved PC2100 DDR SDRAM running at up to 266MHz with Advanced ECC and Online Spare capabilities
Maximum 12 GB (6GB max on 400MHz Front Side Bus Models)

Network Controller Two NC7781 PCI-X Gigabit NICs (embedded)

Expansion Slots Slot Number Bus Speed Bus Number Hot Plug PCI Voltage Notes
1
64-bit/133MHz PCI-X
A
No
3.3 Volt
Supported RILOE II slot
2
64-bit/100MHz PCI-X
B
Yes
3.3 Volt
 
3
64-bit/100MHz PCI-X
B
Yes
3.3 Volt
 
NOTE: For more information regarding PCI-X, please see the following URL: www.hp.com/servers/pci-x.
NOTE: All slots can accept universal keyed PCI cards

Storage Controller Smart Array 5i Plus Controller (integrated on system board)

Storage Diskette Drive 1.44 MB Diskette Drive
Optical Drive 24x IDE CD-ROM (Universal Media Bay)
Hard Drives None
NOTE: The system can be operated in single channel (using either the embedded Smart Array 5i Plus controller or a PCI-based controller) or dual channel (with the first 2 drives on 1 channel, driven by the Smart Array 5i Plus controller and 4 drives driven by either the Smart Array 5i Plus or a PCI-based controller).
Maximum Internal
Storage
1.80 TB (6 x 300 GB Ultra320 1")

InterfacesSerial1
Pointing Device (Mouse)1
Graphics1
Keyboard1
External SCSI (VHDCI)1
Network RJ-453 (1 for iLO)
USB2
NOTE: Please see the following URL for additional information regarding USB support:
http://h18004.www1.hp.com/products/servers/platforms/usb-support.html.

Graphics Integrated ATI Rage XL Video Controller with 8-MB SDRAM Video Memory

Form Factor Rack (2U), (3.5-inch)

ProLiant Essentials Foundation Pack Software
HP Systems Insight Manager HP's new HP Systems Insight Manager (HP SIM) helps maximize system uptime and performance and reduce system maintenance costs by providing proactive notification of problems before those problems result in unplanned downtime or reduced productivity. HP SIM are both easy to set up work with the Insight Management Agents, integrated Light-Out and Remote Insight Light-Outs Edition, and Version Control Agents to deliver robust fault, configuration, and asset management as well as remote administration. With HP SIM customers will also be able to take advantage of role-based security; the ability to manage ProLiant, Integrity, and HP 9000 systems; and plug-ins for storage, client, printer, and power management as well as server rapid deployment, performance management, and workload management. For more details on HP SIM visit http://www.hp.com/go/hpsim.
SmartStartSmartStart is a tool that simplifies server setup, providing a rapid way to deploy reliable and consistent server configurations. For more information, please visit the SmartStart Web site at:
http://www.hp.com/servers/smartstart
SmartStart version supported (minimum): SmartStart 6.0
Management AgentsThe Management Agents form the foundation for HP's Intelligent Manageability strategy. They provide direct, browser-based access to in-depth instrumentation built into HP servers, workstations, desktops, and portables, and send alerts to Insight Manager 7 and other enterprise management applications in case of subsystem or environmental failures. For additional information about the Management Agents and other management products from, HP please visit the management Web site at:
http://www.hp.com/servers/manage
Subscribers Choice Subscriber's Choice Driver and Support Alerts/Notifications is a web-based email subscription service that provides automatic delivery of software and driver change notifications for ProLiant products. Sign up at http://www.hp.com/go/subscriberschoice
and customize your profile to receive various new alerts as they become available, on a weekly or monthly basis.
ROMPaq, support software, and configuration utilities The latest software, drivers, and firmware fully optimized and tested for your ProLiant server and options available in SmartStart or downloadable from Software and Drivers download pages, linked from the SmartStart website at http://www.hp.com/servers/smartstart.
Survey Utility and diagnostics utilities The most advanced configuration analysis, reporting and troubleshooting utilities used by HP and at your fingertips, available in SmartStart.
Optional ProLiant Essentials Value Packs Optional software offerings that selectively extend the functionality of an Adaptive Infrastructure to address specific business problems and needs:
  • Rapid Deployment Pack – an automated solution for multi-server deployment and provisioning, enabling companies to quickly and easily adapt to changing business demands.
  • Workload Management Pack – provides easier management of complex environments, improving overall server utilization and enabling Windows 2000 customers for the first time to confidently deploy multiple applications on a single multiprocessor ProLiant Server.
  • Integrated Lights-Out Advanced Pack – upgrades the Integrated Lights-Out processor to full virtual presence and control with graphical console and virtual media.
  • Recovery Server Option Pack – entry-level high availability software that will provide reliable protection and increased uptime against server hardware and operating system failures.
  • Performance Management Pack – a performance management solution that identifies and explains hardware performance bottlenecks on ProLiant servers and attached options enabling users to better utilize their valuable resources.
  • Intelligent Networking Pack - detects and analyzes network bottlenecks or broken network linkages and steers traffic to the optimum route based on network conditions
NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer to http://www.hp.com/servers/proliantessentials or the various ProLiant Essentials Value Pack product QuickSpecs for more information.
NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials.

Industry Standard Compliance ACPI 1.0b Compliant
PCI 2.2 Compliant
WOL Support
Microsoft® Logo certifications
USB 1.1

Manageability Insight Manager 7
HP Systems Insight Manager
Redundant ROM
Remote Flash ROM
Management Agent
Automatic Server Recovery (ASR)
Integrated Management Log
Drive Parameter Tracking (with Smart Array Controllers)
Dynamic Sector Repairing (with Smart Array Controllers)
Hot Spare Boot
(NOTE: Upon the event of a failed processor or VRM in a multi-processing environment, the system will automatically reboot and use the remaining good processor(s).)
Pre-Failure Warranty (covers processors, hard drives and memory)

Remote Manageability Integrated Lights Out (iLO)
Integrated Lights Out Advanced Pack (optional)
Remote Insight Lights-Out Edition ll (optional)

Security Power-on password
Keyboard password
Diskette drive control
Diskette boot control
QuickLock, Network Server Mode
Serial interface control
Administrator's password
Disk configuration lock

Server Power Cords One Lowline NEMA power cord and One Highline IEC Power cord ships standard

Power Supply 400 Watt, CE Mark Compliant
Optional Hot Plug AC Redundant Power Supply and DC Redundant Power Supply

System Fans 5 fans ship standard. 8 total supported internally for full redundancy
  NOTE: The additional 3 fans are available via Redundant Fan Option Kit (PN 293048-B21).

Required CablingFor required cabling information, refer to the Web site at:
http://h18000.www1.hp.com/products/servers/proliantDL380/.

OS SupportMicrosoft Windows NT® Server
Microsoft Windows 2000
Novell NetWare
Caldera OpenUNIX 8
LINUX (Red Hat, SuSE)
NOTE: For a more complete and up-to-date listing of supported OSs and versions, please visit our OS Support Matrix at: http://www.hp.com/go/supportos
NOTE: For an up-to-date listing of the latest drivers available for the ProLiant DL380 G3, please see: http://h18023.www1.hp.com/support/files/server/us/index.html.
NOTE: For a more complete and up-to-date information on Linux support, please visit HP Linux Web site at: http://h18000.www1.hp.com/products/servers/linux/hpLinuxcert.html.
NOTE: For more complete and up-to-date information on how to buy server operating systems from HP please visit the OS product site at: http://h18004.www1.hp.com/products/servers/software/OEM.html

Rack Airflow Requirements

Rack 10000 series Cabinets
The increasing power of new high-performance processor technology requires increased cooling efficiency for rack-mounted servers. The 10000 Series Racks provide enhanced airflow for maximum cooling, allowing these racks to be fully loaded with servers using the latest processors.

CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment:

    • Front and rear doors: If your 42U server rack includes closing front and rear doors, you must allow 830 square inches (5,350 sq cm) of hole evenly distributed from top to bottom to permit adequate airflow (equivalent to the required 64 percent open area for ventilation).
    • Side: The clearance between the installed rack component and the side panels of the rack must be a minimum of 2.75 inches (7 cm).

CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage.

NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation CD provided with the server, or to the server documentation located in the Support section at the following URL: http://h18000.www1.hp.com/products/servers/proliantdl380/index.html.

Rack Kit Tool-free support for racks with square mounting holes (including Compaq/HP 7000, 9000, 10000 and H9 series), with an adjustment range of 24" - 36".

Telco Rack SupportDL380 G3 Telco Rack Kit:
Support for all 2-post Telco racks requires the use of the standard rack kit and an additional option kit from Rack Solutions (http://www.racksolutions.com/hp).

HP Factory Express CapabilitiesHP Factory Express gives you the flexibility to choose from a full menu of factory capabilities all in one manufacturing facility, in one process, with one touch giving you full control and access to HP's World class manufacturing facility anytime. This approach provides you the speed to deploy your IT needs, with total quality assurance, reliability, and predictability to lower your total cost of ownership by letting HP install, rack, and customize your software and hardware options for you.

Service and Support Three-year limited warranty, including hardware diagnostic support, pre-failure warranty (coverage of hard drives, memory and processors). The warranty is fully supported by HP Services and a worldwide network of resellers and service providers. In addition 90-day's getting started software telephone support may be covered under the warranty or available for an additional fee. Enhancements to warranty services are available through HP Care Pack services.

NOTE: Limited warranty includes 3 year parts, 3 year labor, 3-year next business day on-site support

Care Pack services provide a range of life cycle support options that let you choose the service levels that meet your business requirements, from basic to mission-critical.

A full range of HP Care Pack hardware and software services are available including:

  • Installation and start up
  • Education courses
  • Extended onsite hardware coverage hours from same business day 13 hours, 5 day to 24 hours, 7 days call window with options including 4-hour response or 6-hour Call To Repair
  • Comprehensive range of software technical support for Microsoft, Linux, ProLiant Essentials and VMWare-based IT solutions helping to deliver high level of application availability. Response times range from 30 mins for critical problems to 2 hours.
  • System Management, Performance Services and Mission Critical Support Solution

HP Care Pack Services include HP branded hardware options qualified for the server, purchased at the same time or afterwards, internal to the enclosure, as well as 22" and smaller external monitors and tower UPS options up to 3KVA. 22" and smaller external monitors will be covered at the same service level and coverage period as the server. For servers or storage systems installed within a rack, service also covers all HP qualified rack options installed within the same rack.

NOTE: For more information on HP Care Pack services, contact any of our worldwide sales offices or resellers or visit our worldwide Web site on the internet at: http://www.hp.com/hps/carepack
NOTE:
For more complete information on HP Services offerings, customers and resellers, please visit us at:http://www.hp.com/hps
NOTE:
Additional information regarding worldwide limited warranty and technical support is available at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html
contents
 Overview      Standard Features      Models      Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Models

DL380R03 X3.2-2MB/533, 1GB
352529-001
Processor (1) Intel Xeon Processor 3.2 GHz standard (up to 2 supported)
Cache Memory 512KB level 2 cache and 2-MB level 3 cache
Memory 1 GB (Standard) to 12 GB (Maximum) of 2-way interleaved capable PC2100 DDR SDRAM running at 266MHz with Advanced ECC capabilities
Network Controller (2) NC7781 PCI-X Gigabit NIC (embedded)
Storage Controller Smart Array 5i Plus Controller (integrated on system board)
Hard Drives None ship standard
Internal Storage 1.80 TB max (with optional hard drives)
Optical Drive 24x IDE CD-ROM (Universal Media Bay)
Diskette Drive 1.44 MB Diskette Drive
Form Factor Rack (2U), (3.5-inch)

DL380R03 X3.2-1MB/533, 1GB
333705-001
Processor (1) Intel Xeon Processor 3.2 GHz standard (up to 2 supported)
Cache Memory 512KB level 2 cache and1-MB level 3 cache
Memory 1 GB (Standard) to 12 GB (Maximum) of 2-way interleaved capable PC2100 DDR SDRAM running at 266MHz with Advanced ECC capabilities
Network Controller (2) NC7781 PCI-X Gigabit NIC (embedded)
Storage Controller Smart Array 5i Plus Controller (integrated on system board)
Hard Drives None ship standard
Internal Storage 1.80 TB max (with optional hard drives)
Optical Drive 24x IDE CD-ROM (Universal Media Bay)
Diskette Drive 1.44 MB Diskette Drive
Form Factor Rack (2U), (3.5-inch)

DL380R03 X3.06-1MB/533, 1GB
333704-001
Processor (1) Intel Xeon Processor 3.06 GHz standard (up to 2 supported)
Cache Memory 512KB level 2 cache and1-MB level 3 cache
Memory 1 GB (Standard) to 12 GB (Maximum) of 2-way interleaved capable PC2100 DDR SDRAM running at 266MHz with Advanced ECC capabilities
Network Controller (2) NC7781 PCI-X Gigabit NIC (embedded)
Storage Controller Smart Array 5i Plus Controller (integrated on system board)
Hard Drives None ship standard
Internal Storage 1.80 TB max (with optional hard drives)
Optical Drive 24x IDE CD-ROM (Universal Media Bay)
Diskette Drive 1.44 MB Diskette Drive
Form Factor Rack (2U), (3.5-inch)

DL380R03 X2.8-1MB/533, 1GB
352526-001
Processor (1) Intel Xeon Processor 2.8 GHz standard (up to 2 supported)
Cache Memory 512KB level 2 cache and1-MB level 3 cache
Memory 1 GB (Standard) to 12 GB (Maximum) of 2-way interleaved capable PC2100 DDR SDRAM running at 266MHz with Advanced ECC capabilities
Network Controller (2) NC7781 PCI-X Gigabit NIC (embedded)
Storage Controller Smart Array 5i Plus Controller (integrated on system board)
Hard Drives None ship standard
Internal Storage 1.80 TB max (with optional hard drives)
Optical Drive 24x IDE CD-ROM (Universal Media Bay)
Diskette Drive 1.44 MB Diskette Drive
Form Factor Rack (2U), (3.5-inch)

DL380R03 X3.06-512KB/533, 1GB
310587-001
Processor (1) Intel Xeon Processor 3.06 GHz standard (up to 2 supported)
Cache Memory 512-KB level 2 cache
Memory 1 GB (Standard) to 12 GB (Maximum) of 2-way interleaved capable PC2100 DDR SDRAM running at 266MHz, with Advanced ECC capabilities
Network Controller (2) NC7781 PCI-X Gigabit NIC (embedded)
Storage Controller Smart Array 5i Plus Controller (integrated on system board)
Hard Drives None ship standard
Internal Storage 1.80 TB max (with optional hard drives)
Optical Drive 24x IDE CD-ROM (Universal Media Bay)
Diskette Drive 1.44 MB Diskette Drive
Form Factor Rack (2U), (3.5-inch)

DL380R03 X2.8-512KB/400, 1GB
349201-001
Processor (1) Intel Xeon Processor 2.8 GHz standard (up to 2 supported)
Cache Memory 512-KB level 2 cache
Memory 1GB (Standard) to 6 GB (Maximum) of 2-way interleaved capable PC2100 DDR SDRAM running at 200MHz, with Advanced ECC capabilities
Network Controller (2) NC7781 PCI-X Gigabit NIC (embedded)
Storage Controller Smart Array 5i Plus Controller (integrated on system board)
Hard Drives None ship standard
Internal Storage 1.80 TB max (with optional hard drives)
Optical Drive 24x IDE CD-ROM (Universal Media Bay)
Diskette Drive 1.44 MB Diskette Drive
Form Factor Rack (2U), (3.5-inch)

DL380R03 X2.8-512KB/400, 1GB, W2K
331441-001
Processor (1) Intel Xeon Processor 2.8 GHz standard (up to 2 supported)
Cache Memory 512-KB level 2 cache
Memory 1 GB (Standard) to 6 GB (Maximum) of 2-way interleaved capable PC2100 DDR SDRAM running at 200MHz, with Advanced ECC capabilities
Network Controller (2) NC7781 PCI-X Gigabit NIC (embedded) 10/100/1000 WOL (Wake on LAN) (embedded)
Storage Controller Smart Array 5i Plus Controller (integrated on system board)
Hard Drives None ship standard
Internal Storage 1.80 TB max (with optional hard drives)
Optical Drive 24x IDE CD-ROM (Universal Media Bay)
Form Factor Rack (2U), (3.5-inch)
  Diskette Drive 1.44 MB Diskette Drive
  OS Windows 2000 Server + 5 CALs standard with W2K model (not pre-installed)

DL380R03 X2.4-512KB/400, 1GB
349200-001
Processor (1) Intel Xeon Processor 2.4 GHz standard (up to 2 supported)
Cache Memory 512-KB level 2 cache
Memory 1GB (Standard) to 6 GB (Maximum) of 2-way interleaved capable PC2100 DDR SDRAM running at 200MHz, with Advanced ECC capabilities
Network Controller (2) NC7781 PCI-X Gigabit NIC (embedded)
Storage Controller Smart Array 5i Plus Controller (integrated on system board)
Hard Drives None ship standard
Internal Storage 1.80 TB max (with optional hard drives)
Optical Drive 24x IDE CD-ROM (Universal Media Bay)
Diskette Drive 1.44 MB Diskette Drive
Form Factor Rack (2U), (3.5-inch)
contents
 Overview      Standard Features      Models      Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Options

ProLiant DL380 G3
Unique Options
DL380 G3 Redundant Fan Option Kit
NOTE: Hot Plug Redundant Fan Option Kit (PN 293048-B21) contains three fans per kit.
293048-B21
Hot Plug AC Redundant Power Supply Module (NEMA cord)
313054-001
Hot Plug AC Redundant Power Supply Module (IEC cord)
313054-B21

ProLiant Essentials
Value Pack Software
Rapid Deployment Pack, 1 User, V1.x
NOTE: This license allows 1 server to be managed and deployed via the Deployment Server.

267196-B21

Rapid Deployment Pack, 10 Users, V1.x
NOTE: This license allows 10 servers to be managed and deployed via the Deployment Server.
269817-B21
ProLiant Essentials Workload Management Pack (Featuring Compaq Resource Partitioning Manager version 2.0)
303284-B21
Flexible Quantity License Kit
302127-B21
License-Only - for use with a Master License Agreement
302128-B21
ProLiant Essentials Recovery Server Option Pack
280189-B21
ProLiant Essentials Performance Management Pack, Single License
NOTE: This license allows 1 server to be managed by Performance Management Pack.
306696-B21
ProLiant Essentials Performance Management Pack, 10 Pack Server License
374055-B21
Performance Management Pack, flexible license kit
NOTE: A single pack is shipped with a single license key for the total number of licenses ordered
306697-B21
ProLiant Essentials Integrated Lights-Out Advanced Pack
(Featuring: sophisticated virtual administration features for ultimate control of servers in the data centers and remote sites)
263825-B21
ProLiant Essentials Intelligent Networking Pack, 1 License
372906-B21
ProLiant Essentials Intelligent Networking Pack Flex License
372950-B21
ProLiant Essentials Intelligent Networking Pack Track License
372951-B21
ProLiant Essentials Virtual Machine Management Pack, Single-Server License
NOTE: For use with a single server. Contains one license with a unique license activation key and documentation.
372214-B21
ProLiant Essentials Virtual Machine Management Pack, Flexible-Quantity License
NOTE: For use with multiple servers. This part number can be used to purchase multiple licenses with a single activation key.
372215-B21
ProLiant Essentials Virtual Machine Management Pack, Tracking License
NOTE: For use with signed and implemented Activation Key Agreements only. Purchase of this part number entitles the customer to deploy additional licenses of the product under the terms of the existing Activation Key Agreement.
372216-B21
ProLiant Essentials Vulnerability and Patch Management Pack, Single-Server License
371645-B21
ProLiant Essentials Vulnerability and Patch Management Pack, 10-Server License
372029-B21
ProLiant Essentials Vulnerability and Patch Management Pack, Flexible-Quantity License
371646-B21
ProLiant Essentials Vulnerability and Patch Management Pack, Tracking license for new servers
371647-B21
ProLiant Essentials Vulnerability and Patch Management Pack, Tracking license for installed servers
378372-B21
NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer to http://www.hp.com/servers/proliantessentials or the various ProLiant Essentials Value Pack product QuickSpecs for more information.
NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials.

Software HP digital asset protection
302316-001

Processor Intel Xeon X3.2-2MB/533MHz Processor Option Kit
NOTE: The 3.2GHz processor option kits are not backwards compatible; they cannot be used to upgrade systems purchased with 2.4 or 2.8GHz 400MHz Front Side Bus processors. This processor option kit supports the ProLiant ML370 G3 and ProLiant DL380 G3 servers.
352568-B21
  Intel Xeon X3.2-1MB/533MHz Processor Option Kit
NOTE: The 3.2GHz processor option kits are not backwards compatible; they cannot be used to upgrade systems purchased with 2.4 or 2.8GHz 400MHz Front Side Bus processors. This processor option kit supports the ProLiant ML370 G3 and ProLiant DL380 G3 servers.
333714-B21
  Intel Xeon X3.06-1MB/533MHz Processor Option Kit
NOTE: The 3.06GHz processor option kits are not backwards compatible; they cannot be used to upgrade systems purchased with 2.4 or 2.8GHz 400MHz Front Side Bus processors. This processor option kit supports the ProLiant ML370 G3 and ProLiant DL380 G3 servers.
333713-B21
  Intel Xeon X2.80-1MB/533MHz Processor Option Kit
NOTE: The 3.06GHz processor option kits are not backwards compatible; they cannot be used to upgrade systems purchased with 2.4 or 2.8GHz 400MHz Front Side Bus processors. This processor option kit supports the ProLiant ML350 G3, ProLiant ML370 G3 and ProLiant DL380 G3 servers.
352567-B21
  Intel Xeon 3.06 GHz-512KB/533MHz Processor Option Kit
NOTE: The 3.06GHz processor option kits are not backwards compatible; they cannot be used to upgrade systems purchased with 2.4 or 2.8GHz 400MHz Front Side Bus processors. This processor option kit supports the ProLiant ML350 G3, ProLiant ML370 G3 and ProLiant DL380 G3 servers.
257916-B21
  Intel Xeon 2.80 GHz-512KB/400MHz Processor Option Kit
NOTE: This processor option kit (PN 257915-B21) is not forwards compatible; it cannot be used in systems purchased with 533MHz Front Side Bus processors. This processor option kit supports the ProLiant ML370 G3 and ProLiant DL380 G3 servers.
257915-B21
  Intel Xeon 2.40 GHz-512KB/400MHz Processor Option Kit
NOTE: This processor option kit (PN 257913-B21) is not forwards compatible; it cannot be used in systems purchased with 533MHz Front Side Bus processors. This processor option kit supports the ProLiant ML370 G3 and ProLiant DL380 G3 servers.
257913-B21

Memory 512MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (2 x 256 MB)
300678-B21
 1024MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (2 x 512 MB)
300679-B21
 2048-MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (2x1024 MB)
300680-B21
 4096MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (2x 2048 MB)
NOTE: The 4096MB of Advanced ECC PC2100 DDR Memory kit (300682-B21) can only be used in 533MHz Front Side Bus models.
300682-B21

Optical Drives Slimline CD-RW/DVD-ROM Combo Option Kit
331903-B21
  Slimline DVD-ROM Drive (8X/24X) Option Kit (Servers)
264007-B21

Hard Drives Ultra320 SCSI – Universal Hot Plug
300-GB 10,000 rpm U320 Universal Hard Drive (1")
350964-B22
146.8-GB 10,000 rpm U320 Universal Hard Drive (1")
286716-B22
72.8-GB 10,000 rpm U320 Universal Hard Drive (1")
286714-B22
72.8-GB 15,000 rpm U320 Universal Hard Drive (1")
286778-B22
36.4-GB 15,000 rpm U320 Universal Hard Drive (1")
286776-B22
NOTE: All U320 Universal Hard Drives are backward compatible to U2 or U3 speeds. U320 drives require an optional U320 Smart Array Controller to support U320 transfer rates.
NOTE: Please see the Hard Drive QuickSpecs for Technical Specifications such as capacity, height, width, interface, transfer rate, seek time, physical configuration, and operating temperature:
U320 Hard Drive QS:
http://h18000.www1.hp.com/products/quickspecs/11531_na/11531_na.html

Storage Controllers Battery Backed Write Cache Enabler Option Kit
255514-B21

Smart Array 5304/256 Controller

283551-B21

Smart Array 6402/128 Controller
273915-B21
Smart Array 6404/256 Controller
273914-B21
Smart Array 641 Controller
291966-B21
Smart Array 642 Controller
291967-B21

128-MB Cache Module for Smart Array 5302 Controller

153506-B21

256-MB Battery-Backed Cache Module
NOTE: This 256-MB Battery-Backed Cache Module supports the Smart Array 5300 series controllers, HP StorageWorks Modular Smart Array 1000 and the HP StorageWorks Modular Smart Array 500.

254786-B21

256MB DDR, Battery-Backed Cache Upgrade Kit for SA-6400
NOTE: This 256-MB DDR, Battery-Backed Cache upgrade kit supports the Smart Array 6400 series controller only.
273913-B21
128MB Battery-Backed Cache Enabler
NOTE: This 128MB BBWC supports the Smart Array 641 Controller and Smart Array 642 Controller.
351580-B21
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter
268351-B21
Ultra320 Expansion Module for SA-6402
273911-B21
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
284688-B21
NOTE: Please see the following Controller or SCSI Adapter QuickSpecs for Technical Specifications such as PCI Bus, PCI Peak Data Transfer Rate, SCSI Protocols supported, SCSI Peak Data Transfer Rate, Channels, SCSI Ports, Drives supported, Cache, RAID support, and additional information:
http://h18000.www1.hp.com/products/quickspecs/10640_na/10640_na.html
(Smart Array 5300 Series)
http://h18000.www1.hp.com/products/quickspecs/11746_na/11746_na.html
(Smart Array 6400 Series)
http://h18000.www1.hp.com/products/quickspecs/12067_na/12067_na.html
(Smart Array 641)
http://h18000.www1.hp.com/products/quickspecs/12069_na/12069_na.html
(Smart Array 642)
http://h18000.www1.hp.com/products/quickspecs/10429_na/10429_na.html
(SCSI Adapter)
http://h18000.www1.hp.com/products/quickspecs/11555_na/11555_an.html
(U320 Adapter)

Communications NC6170 Dual Port PCI-X 1000SX Gigabit Server Adapter
313879-B21
  NC6770 PCI-X Gigabit Server Adapter, 1000-SX
244949-B21
  NC7170 Dual Port PCI-X 1000T Gigabit Server Adapter
313881-B21
  NC1020 Cu Gigabit Server Adapter 32 PCI Single Port 353377-B21
  NC7771 PCI-X 10/100/1000-T Server Adapter
290563-B21
  NOTE: Any NIC on the option list can be used for redundancy with the embedded NC7781 Network Controller

DC Power Supply DC Power Supply for the DL380 (48V)

268290-B21

NOTE: The ProLiant DL380 G3 ships standard with a 100-240 volt auto-switching AC power supply. Each 48-volt DC option kit (PN 268290-B21) contains one power supply. Therefore, to convert to redundant DC power supplies, two must be purchased.

 


Redundant Options Hot Plug AC Redundant Power Supply Module (NEMA cord)

313054-001

Hot Plug AC Redundant Power Supply Module (IEC cord)

313054-B21


Management Options

Remote Insight Lights-Out Edition II

227251-001

NOTE: USB Virtual Media Not Supported. 
NOTE: The RILOE II USB Virtual Media feature is not supported on the 2.40 and 2.80 GHz versions of the ProLiant DL380 G3 and ProLiant ML370 G3 servers. The RILOE II cannot be used to connect the local client floppy and CD devices as USB virtual devices to the remote server. All other RILOE II features are supported on these servers. The non-USB based RILOE II Virtual Floppy feature is still supported, allowing you to perform functions such as remote ROM upgrades and server deployment. The Virtual Floppy feature requires loading the floppy image in to the RILOE II. For more details, please refer to the user guide of the RILOE II. 

Security

HP/Atalla AXL600L SSL Accelerator Card for ProLiant Servers

524545-B21

AXL300 Accelerator PCI Card for ProLiant Servers

227933-B21


Tape Drives
NOTE: External tape devices, including both tape drives and tape arrays/enclosures, can be directly connected to the VHDCI SCSI port located on the back of the server. Use of a SCSI adapter to connect these devices is optional, not required.
 
External, Rack-Mount, and Array Module Ultrium Tape Drives
HP StorageWorks Ultrium 215 Tape Drive, External (Carbon)
Q1545A
HP StorageWorks Ultrium 215 rack-mount (Carbon) - Single drive installed in a 3U rack-mount kit
350544-B21
HP StorageWorks Ultrium 215 Array Module (Carbon) - Offline hot-swap drive for Tape Array 5300
C7492B
HP StorageWorks Ultrium 230 Tape Drive, External (Carbon)
Q1517A
HP StorageWorks Ultrium 230, Rack-mount (Carbon) - Single drive installed in a 3U rack-mount kit
350545-B21
HP StorageWorks Ultrium 230 Array Module (Carbon) - Offline hot-swap drive for Tape Array 5300
C7470B
HP StorageWorks Ultrium 460 Tape Drive, External (Carbon)
Q1520A
HP StorageWorks Ultrium 460, Rack-mount (Carbon) - Single drive installed in a 3U rack-mount kit
350546-B21
HP StorageWorks Ultrium 460 Array Module (Carbon) - Offline hot-swap drive for Tape Array 5300
Q1512B
HP StorageWorks Ultrium 960 Tape Drive, External (Carbonite)
Q1539A
HP StorageWorks Ultrium 960 Rack-mount (Carbonite) - Single drive installed in a 3U rack-mount kit
Q1595A
NOTE: Please see the HP StorageWorks Ultrium Tape Drive QuickSpecs for additional options such as controllers, media, and other related items:
http://h18006.www1.hp.com/products/quickspecs/11739_na/11739_na.html
http://h18006.www1.hp.com/products/quickspecs/12128_na/12128_na.html
For an up-to-date listing of the latest O/S and software support details for HP Ultrium tape drives, please visit: http://www.hp.com/go/connect.
 
External, Hot-Plug, and Array Module DAT Drives  
HP StorageWorks DAT 72 Tape Drive, External (Carbon)
Q1523A
HP StorageWorks DAT 72 Tape Drive, Internal Hot-Plug (Carbon)
Q1529A
HP StorageWorks DAT 72 Array Module (Carbon) - Offline hot-swap drive for Tape Array 5300
Q1524B
HP StorageWorks DAT 40 Tape Drive, External (Carbon)
C5687C
HP StorageWorks DAT 40 Tape Drive, Internal Hot-Plug (Carbon)
Q1546A
HP StorageWorks DAT 40 Array Module (Carbon) - Offline hot-swap drive for Tape Array 5300
C7497B
HP StorageWorks DAT 24e Tape Drive, External (Flint)
C1556D
HP StorageWorks DAT 24 Array Module (Carbon) - Offline hot-swap drive for Tape Array 5300
C7498A
NOTE: Please see the DAT Tape Drive QuickSpecs for controllers, media, and other options:
http://h18000.www1.hp.com/products/quickspecs/11883_na/11883_na.html
For an up-to-date listing of the latest O/S and software support details for HP DAT drives, please visit: http://www.hp.com/go/connect.
 
External DLT VS Tape Drives
 
HP StorageWorks DLT VS80 Tape Drive, External (Carbon)
337699-B22
NOTE: Please see the DLT VS80 Tape Drive QuickSpecs for additional options such as host bus adapters, controllers, media, and other options:
http://h18006.www1.hp.com/products/quickspecs/11403_na/11403_na.HTM
For an up-to-date listing of the latest O/S and software support details for the DLT VS80, please visit: http://www.hp.com/go/connect.
 
External SDLT Tape Drives  
HP StorageWorks SDLT 320 Tape Drive, External (Carbon)
257319-001
NOTE: Please see the SDLT 320 Tape Drive QuickSpecs for additional options such as adapters, controllers, and media.
http://h18006.www1.hp.com/products/quickspecs/11840_na/11840_na.html
For an up-to-date listing of the latest O/S and software support details for HP SDLT tape drives, please visit: http://www.hp.com/go/connect.
 
Rack-Mount Tape Drive Enclosures
 
HP StorageWorks 1U Rack-Mount Kit
NOTE: The 1U Rack-mount Kit can support up to 2 half-height tape drives and compatible with multiple Single-Ended and LVD SCSI tape drives including DAT 24, DAT40, DAT72, DLT VS 80, and Ultrium 215 tape drives.
A7445A
HP StorageWorks 3U Rack-Mount Kit
NOTE: The 3U Rack-Mount Kit can support up to 2 full-height or 4 half-height tape drives and compatible with multiple Single-Ended and LVD SCSI tape drives including DAT, DLT VS80, SDLT 320, Ultrium 215, Ultrium 230, and Ultrium 460 Tape Drives.
274338-B21
HP StorageWorks 5U Rack-Mount Kit
NOTE: The 5U Rack-Mount Kit can support up to 4 full-height tape drives and is compatible with SDLT 320, Ultrium 230, and Ultrium 460 tape drives.
274339-B21
NOTE: Please see the Rack-Mount Tape Drive Kits QuickSpecs for additional information regarding these kits:
http://h18000.www1.hp.com/products/quickspecs/10854_na/10854_na.html
 
HP StorageWorks Tape Array 5300
C7508A
NOTE: The Tape Array 5300 is a 3U enclosure that supports up to 2 full-height or 4 half-height hot-swap array modules, including DAT and Ultrium tape drives. Cables and terminators are not included and must be ordered separately.
NOTE: Please see the Tape Array 5300 QuickSpecs for additional information regarding this product.

http://h18000.www1.hp.com/products/quickspecs/11878_na/11878_na.html
Accessories for 3U & 5U Rack-mount Tape Drive Kits
LVD Cable Kit, VHDCI/HD68
NOTE: For use with the 3U Rack-mount Kit and 5U Rack-mount Kit only.
168048-B21
LVD Cable Kit, HD68/HD68
NOTE: For use with the 3U Rack-mount Kit and 5U Rack-mount Kit only.
242381-B21
Accessories for 3U & 5U Rack-mount Tape Drive Kits
PSU/Fan Upgrade Kit - Redundant hot-swap power supply unit and fan for Tape Array 5300.
68-pin HD multi-mode terminator
C2364A
1.0m 68-pin VHDCI to 68-pin HD cable
C2361B
2.5m 68-pin VHDCI to 68-pin HD cable
C2362B
5.0m 68-pin VHDCI to 68-pin HD cable
C2365A
10.0m 68-pin VHDCI to 68-pin HD cable
C2363B
0.5m 68-pin HDI to 68-pin HD cable LVD/SE
C2978B
1.5m 68-pin HDI to 68-pin HD cable LVD/SE
C2979B
0.9m 68-pin HDI to 68-pin HD cable LVD/SE
C2911C
2.5m 68-pin HDI to 68-pin HD cable LVD/SE
C2924C
NOTE: For use with Tape Array 5300 only.  

Tape Autoloaders DAT Autoloader
HP StorageWorks DAT 72x6 External Autoloader
Q1567A
NOTE: Please see the DAT Tape Autoloader QuickSpecs for additional options such as host bus adapters, controllers and media:
http://h18000.www1.hp.com/products/quickspecs/11985_na/11985_na.html

 
HP StorageWorks DAT 40x6 Tape Autoloader, External (Flint) C5717C
NOTE: Please see the DAT Tape Autoloader QuickSpecs for additional options such as host bus adapters, controllers and media:
http://h18000.www1.hp.com/products/quickspecs/11985_na/11985_na.html
HP StorageWorks 1/8 Tape Autoloader  
1/8 Ultrium 460 Tape Autoloader, Tabletop
AA927A
1/8 SDLT 320 Tape Autoloader, Tabletop AA926A
1/8 Ultrium 230 Tape Autoloader, Tabletop C9572CB
1/8 DLT VS80 Tape Autoloader, Tabletop C9264CB
1/8 Tape Autoloader Rackmount Kit C9268R
NOTE: Required to install the 1/8 tape autoloader in a standard 19-inch rack  
NOTE: Please reference the 1/8 Tape Autoloader QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs  
HP StorageWorks SSL1016 Tape Autoloader  
SSL1016 Ultrium 460 Tape Autoloader
330821-B21
SSL1016 SDLT 320 Tape Autoloader
330816-B21
NOTE: Please reference the SSL1016 Tape Autoloader QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs.  

Tape Libraries HP StorageWorks MSL6000 Tape Library  
  MSL6030, 1 drive, 30 slots, Ultrium 460, RM
330731-B22
  MSL6030, 2 drive, 30 slots, Ultrium 460, RM
330731-B23
  MSL6030, 1 drive, 30 slots, Ultrium 460, RM with embedded FC router
330731-B24
  MSL6030, 2 drive, 30 slots, Ultrium 460, RM with embedded FC router
330731-B25
  MSL6030, 1 drive, 30 slots, Ultrium 460, TT
330788-B21
  MSL6030, 2 drive, 30 slots, Ultrium 460, TT
330788-B22
  MSL6060, 2 drive, 60 slot, Ultrium 460, RM
331196-B21
  MSL6060, 2 drive, 60 slot, Ultrium 460, RM with embedded FC router 331196-B22
  MSL6060, 2 drive, 60 slot, Ultrium 460, TT 331195-B21
  NOTE: Please reference the MSL6000 Tape Library QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs.  
  HP StorageWorks MSL5026S2 Tape Library  
  MSL5026S2, 1 drive, 26 slots, SDLT 320, RM 293472-B22
  MSL5026S2, 2 drive, 26 slots, SDLT 320, RM 293472-B23
  MSL5026S2, 1 drive, 26 slots, SDLT 320, RM with embedded FC router 293472-B24
  MSL5026S2, 2 drive, 26 slots, SDLT 320, RM with embedded FC router 293472-B25
  MSL5026S2, 1 drive, 26 slots, SDLT 320, TT 293473-B21
  MSL5026S2, 2 drive, 26 slots, SDLT 320, TT 293473-B22
  NOTE: Please reference the MSL5026S2 Tape Library QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs.  
  HP StorageWorks MSL5052S2 Tape Library
 
  MSL5052S2, 2 drive, 52 slots, SDLT 320, RM
293474-B21
  MSL5052S2, 2 drive, 52 slots, SDLT 320, RM with embedded FC router
293474-B24
  MSL5052S2, 2 drive, 52 slots, SDLT 320, TT 293476-B21
  NOTE: Please reference the MSL5052S2 Tape Library QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs.  
  HP StorageWorks MSL5030 Tape Library
 
  MSL5030, 1 drive, 30 slots, Ultrium 230, RM
301897-B22
  MSL5030, 2 drive, 30 slots, Ultrium 230, RM
301897-B23
  MSL5030, 1 drive, 30 slots, Ultrium 230, RM with embedded FC router
301897-B24
  MSL5030, 2 drive, 30 slots, Ultrium 230, RM with embedded FC router
301897-B25
  MSL5030, 1 drive, 30 slots, Ultrium 230, TT
301898-B21
  MSL5030, 2 drive, 30 slots, Ultrium 230, TT
301898-B22
  NOTE: Please reference the MSL5030 Tape Library QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs.  
  HP StorageWorks MSL5060 Tape Library
 
  MSL5060, 2 drive, 60 slots, Ultrium 230, RM
301899-B22
  MSL5060, 2 drive, 60 slots, Ultrium 230, RM with embedded FC router
301899-B23
  MSL5060, 2 drive, 60 slots, Ultrium 230, TT
301900-B21
  NOTE: Please reference the MSL5060 Tape Library QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs.  
  HP StorageWorks ESL E-Series Tape Libraries
 
  ESL Extended 712e Tape Library, 0 drive, 712 LTO slots
AA934A
  ESL Extended 630e Tape Library, 0 drive, 630 SDLT slots
AA935A
  ESL E Ultrium 460 drive kit
AA937A
  ESL E SDLT 320 drive kit
AA936A
  NOTE: Please reference the ESL E-Series Tape Libraries QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs  
  HP StorageWorks ESL9000 Series Tape Libraries
 
  ESL9595 Extended Tape Library, 0 drive, 400 slots (card cage, Interface Mgr card, Command View license)
343378-B21
  ESL9322 Extended Tape Library, 0 drive, 222 slots (card cage, Interface Mgr card, Command View license) 343377-B21
  ESL9000 Ultrium 460 drive kit
330834-B21
  ESL9000 Ultrium 230 drive kit
301930-B21
  ESL9000 SDLT 320 drive kit
293414-B21
  NOTE: Please reference the ESL9000 Series Tape Libraries QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs.  

Magneto-Optical Jukeboxes

HP StorageWorks 9.1 GB Mid-range Optical Jukeboxes
 
300mx, 2 drive, 32 slot jukebox C1150M
600mx, 4 drive, 64 slot jukebox
C1160M
700mx, 2 drive, 76 slot jukebox
C1170M
NOTE: Please reference the Magneto-Optical Jukebox data sheets at http://www.hp.com/go/optical for additional information needed to create a complete solution.
 
HP StorageWorks 9.1 GB High-end Optical Jukeboxes
 
1200mx, 4 drive, up to 128 slots
C1104M
1200mx, 6 drive, up to 128 slots
C1105M
2200mx, 4 drive, up to 238 slots
C1111M
2200mx, 6 drive, up to 238 slots
C1107M
2200mx, 10 drive, up to 238 slots
C1110M
NOTE: Please reference the Magneto-Optical Jukebox data sheets at http://www.hp.com/go/optical for additional information needed to create a complete solution.  
Ultra Density Optical Jukeboxes  
1000ux, 2 drive, 32 slot jukebox AA965A
1900ux, 4 drive, 64 slot jukebox AA966A
1900ux, 4 mixed drive, 64 slot jukebox AA968A
2300ux, 2 drive, 76 slot jukebox AA967A
3800ux, 4 drive, 128 slot jukebox AA969A
3800ux, 6 drive, 128 slot jukebox AA970A
7100ux, 4 drive, 238 slot jukebox AA973A
7100ux, 10 drive, 238 slot jukebox AA972A
7100ux, 6 mixed drive, 238 slot jukebox AA974A

HP StorageWorks Modular Smart Array 500 HP StorageWorks Modular Smart Array 500 Generation 2
335880-B21
NOTE: Please see the Modular Smart Array 500 Generation 2 QuickSpecs for additional information including configuration steps and additional options needed for a complete solution at:
http://h18000.www1.hp.com/products/quickspecs/11956_na/11956_na.html

 

Cluster Options ProLiant Cluster Starter Kit 364023-B21
NOTE: For additional information regarding the ProLiant Cluster Starter Kit please see the following QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/11935_na/11935_na.html
 
ProLiant Cluster Kit with OpenView Storage Mirroring

364025-B21

NOTE: For additional information regarding the ProLiant Cluster Kit with OpenView Storage Mirroring please see the following QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/11934_na/11934_na.html
 
ProLiant Cluster HA/F200 for the Entry Level SAN

364026-B21

NOTE: For additional information regarding the ProLiant Cluster for Entry Level SAN please see the following QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/11932_na/11932_na.html
 
ProLiant Cluster HA/F500 for the Enterprise SAN 364024-B21
NOTE: For additional information regarding the ProLiant Cluster HA/F500 for Enterprise SAN please see the following QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/11933_na/11933_na.html
 
HP Serviceguard for Linux ProLiant Cluster
(2 node license cluster kit) A.11.15
NOTE: Kit includes 2 licenses, documentation and an Ethernet crossover cable.
305199-B24
HP Serviceguard for Linux (single license version for ordering flexibility and to ease ordering for larger cluster) A.11.15
NOTE: Kit includes single license version and documentation.
307754-B24
NOTE: For additional information regarding the HP Serviceguard for Linux License, please see the following QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/11518_na/11518_na.html
 
  PDC/O5000-EVA Windows RAC Cluster Kit 252478-B25
  ProLiant Parallel Database Cluster for Linux - Oracle9i Real Application Cluster 308225-B22
  NOTE: For additional information regarding the ProLiant Parallel Database Cluster for Linux, please see the following QuickSpecs at:
http://www5.compaq.com/products/quickspecs/11688_na/11688_na.html
 
  HP Parallel Database Cluster Model PDC/O2000-MSA1000 for Oracle Real Application Cluster on Windows 279406-B24
  NOTE: For additional information regarding the HP Parallel Database Cluster Model PDC/O2000-MSA1000, please see the following QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/10889_na/10889_na.html
 

External Storage - Rack HP StorageWorks Modular Smart Array 30 SB
NOTE: Rack-mountable 14 drive enclosure with single bus, redundant power supplies
302969-B21
HP StorageWorks Modular Smart Array 30 DB
NOTE: Rack-mountable 14 drive enclosure with dual bus, redundant power supplies
302970-B21
NOTE: The Modular Smart Array Enclosure 30 Family supports the Wide Ultra3, Ultra320 1" Hot Plug Hard Drives.  
StorageWorks Modular Smart Array 30 OpenView Storage Mirroring HA Kit - WW 359079-B21
StorageWorks Modular Smart Array 30 OpenView Storage Mirroring HA Kit - Japan 359079-291
StorageWorks Modular Smart Array 30 OpenView Storage Mirroring HA Kit - APD 359079-371
StorageWorks Modular Smart Array 30 OpenView Storage Mirroring HA Kit - EURO 359079-421
Redundant Power Supply 499W 338296-B21
Ultra320 Single Bus I/O Module for MSA30
287484-B21
Ultra320 Dual Bus I/O Module for MSA30
287483-B21

HP StorageWorks Modular Smart Array 1500 cs Modular Smart Array 1500 Controller Shelf AA986A
NOTE: Please see the StorageWorks Modular SAN Array 1500 QuickSpecs for additional options and configuration information at: http://www.hp.com/go/MSA1500cs

HP StorageWorks Modular Smart Array 1000

HP StorageWorks Modular Smart Array 1000

201723-B22
NOTE: Please see the StorageWorks Modular SAN Array 1000 QuickSpecs for additional options and configuration information at:
http://www5.compaq.com/products/quickspecs/11033_na/11033_na.html

Network Storage Router

M2402 2FCX 4SCSI LVD Network Storage Router
262653-B21
M2402 2FCX 4SCSI HVD Network Storage Router
262654-B21
M2402 4 channel LVD SCSI Module
262659-B21
M2402 4 channel HVD SCSI Module
262660-B21
M2402 2 channel FC Module
262661-B21

StorageWorks Options StorageWorks Director 2/64

286809-B21

NOTE: Please see the StorageWorks Director 2/64 QuickSpecs for additional information:
http://h18000.www1.hp.com/products/quickspecs/11003_na/11003_na.html
 
StorageWorks SAN Switch 2/8-EL

322120-B21

StorageWorks SAN Switch 2/8-EL Upgrade

325888-B21

StorageWorks SAN Switch 2/16

322118-B21


UPS and PDU Power
Cord Matrix
Please see the UPS and PDU cable matrix that lists cable descriptions, requirements, and specifications for UPS and PDU units:
ftp://ftp.compaq.com/pub/products/servers/ProLiantstorage/power-protection/powercordmatrix.pdf.

Uninterruptible Power Systems – Rack HP UPS R1500 XR (1440VA, 1340 Watt), Low Voltage

204404-001

HP UPS R3000 XR (2880VA, 2700 Watt), Low Voltage

192186-001

HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage

192186-002

HP UPS R5500 XR, (5000VA, 4500 Watt), High Voltage 326529-D71
HP UPS R12000 XR N+x (200-240V) (hardwired)
NOTE: The UPS R12000 XR has a hardwired input and output connection.
207552-B22

HP Power Distribution Unit with Power Monitoring

HP Power Distribution Unit with Power Monitoring Model S2324 - dual input, 3 phase, 24A
370959-D71
HP Power Distribution Unit with Power Monitoring Model S1324 - single input, 3 phase, 24A
370960-D71
HP Power Distribution Unit with Power Monitoring Model S2140 - dual input, 1 phase, 40A
370961-D71
HP Power Distribution Unit with Power Monitoring Model S1140 - single input, 1 phase, 40A
370962-D71

Modular Power Distribution Units - 1U0U
(Up to 32 outlets)
NOTE: 1U/0U mounting brackets shipped with
the unit (optimized for 10000 and 9000 series racks).

HP Modular Power Distribution Units (mPDU), Low Volt Model, 24A (100-127 VAC)
NOTE: This mPDU (252663-D71) may also be used to connect the low volt model of the UPS R3000 XR.
252663-D71

HP Modular Power Distribution Units (mPDU), High Volt Model, 24A (200-240 VAC)

252663-D72

NOTE: Please see the following Modular Power Distribution Unit (Zero-U/1U Modular PDUs) QuickSpecs for additional options including shorter jumper cables and country specific power cords:
http://h18000.www1.hp.com/products/quickspecs/11041_na/11041_na.html

USB Options USB Easy Access Keyboard (Carbonite/Silver)
DC168B#ABA
  USB Optical Scroll Mouse (Carbonite)
DD441B

Customer Builder Please see the Enterprise Configurator for configuration assistance at: http://www.hp.com/products/configurator.

Third Party Rack Kit Rack Adapter Kit
NOTE: This kit allows HP rack servers to fit in racks that are 24" wide.
332815-B21

HP Rack 5000 Series (Graphite Metallic) HP 5642 Rack-Unassembled
358254-B21

Rack Options for Rack 5000 Series Stabilizer Kit for 5642 rack (Graphite Carbon)
NOTE: The stabilizing kit is used to prevent rack from tipping over.
374493-B21
Baying Kit for 5642 rack (Graphite Carbon)
NOTE: The baying kit is used to join two or more HP 5642 racks.
374499-B21

HP Rack 10000 Series
(Graphite Metallic)

10642 (42U) Infrastructure Rack (Low Voltage)
379006-001
10642 (42U) Infrastructure Rack (High Voltage)
379005-001
HP S10614 (14U) Rack Cabinet - Shock Pallet
292302-B22

HP 10842 (42U, 800mm wide) – Pallet

257415-B21

HP 10842 (42U, 800mm wide) – Shock Pallet

257415-B22

HP 10647 (47U) – Pallet

245160-B21

HP 10647 (47U) – Crated

245160-B23

HP 10642 (42U) – Pallet

245161-B21

HP 10642 (42U) – Shock Pallet

245161-B22

HP 10642 (42U) – Crated

245161-B23

HP 10636 (36U) – Pallet

245162-B21

HP 10636 (36U) – Shock Pallet

245162-B22

HP 10636 (36U) – Crated

245162-B23

HP 10622 (22U) – Pallet

245163-B21

HP 10622 (22U) – Shock Pallet

245163-B22

HP 10622 (22U) – Crated

245163-B23

NOTE: -B21 (pallet) used to ship empty racks shipped on a truck
-B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels)
-B23 (crated) used for air shipments of empty racks

 

NOTE: It is mandatory to use a shock pallet in order to ship racks with equipment installed.

 

NOTE: Please see the Rack 10000 QuickSpecs for Technical Specifications such as height, width, depth, weight, and color:
http://h18000.www1.hp.com/products/quickspecs/10995_na/10995_na.html

 

NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html.

 


Rack Options for HP
Rack 10000 Series
NOTE: For additional information regarding Rack Options, please see the following URL: http://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html.  
HP Rack Light Kit (Neon)
361589-B21
HP Rack Plinth Kit (Carbon)
251960-B21

42U Side Panel – Graphite Metallic

246099-B21

36U Side Panel – Graphite Metallic

246102-B21

47U Side Panel – Graphite Metallic

255486-B21

TFT5600 Rack Keyboard Monitor

221546-001

1U Rack Keyboard & Drawer (Carbon)
257054-001
NOTE: For additional information regarding Rack Options, please see the following URL: http://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html.

HP KVM Switch Options Server Console Switch (KVM), 0 x 1 x 8 port
336044-B21
Server Console Switch (KVM), 0 x 2 x 16 port
336045-B21

IP Console Switch Box (KVM/IP), 1 x 1 x 16

262585-B21

IP Console Switch Box (KVM/IP), 3 x 1 x 16

262586-B21

HP 1x4 USB/PS2 KVM Switch, TT
371301-D71
PS/2 Interface Adapter, 8 pack
262587-B21
PS/2 Interface Adapter, 1 pack
262588-B21
CAT5 KVM Expansion Module
262589-B21
Serial Interface adapter - 1 Pack with power supply
373035-B21
CAT5e Cable 3', 4 pack
263474-B21
CAT5e Cable 6', 8 pack
263474-B22
CAT5e Cable 12', 8 pack
263474-B23
CAT5e Cable 20', 4 pack
263474-B24
CAT5e Cable 40', 1 pack
263474-B25
NOTE: For additional information regarding HP KVM Switches and options, please see the following URL:
http://h18004.www1.hp.com/products/servers/proliantstorage/rack-options/list.html#console
 

Rack Options for Third Party Cabinet Racks

Round hole rack cabinet rail kit
NOTE: Support for racks with round mounting holes (include HP Rack System /E and HP Systems) with an adjustment range of 24"- 36".

293052-B21


HP Factory Express

Factory Installation, Racking, and Customization Services

 

Factory Express Server Configuration Level 1

293355-888

NOTE: Free Installation of HP Options - Installation of HP Options memory, NICs, hard drives, controllers, processors, I/O cards, pre-install standard OEM OS image, and tape drives. Installation fees will apply to all non-HP certified hardware and asset tags. 

Factory Express Server Configuration Level 2

266326-888
NOTE: Includes Level 1 Customer Intent of a ProLiant server and options configuration, OS installation, custom image download, IP addressing, network setting, and custom packaging. Customer unique requirements (quick restore creation, cd duplication, test reports, real-time reporting of server MAC address, password, and RILOE). Customer access, validation and control through VPN (price/server). 
Factory Express Rack Integration Level 3 with 1 - 3 servers or storage enclosures
325736-888
Factory Express Rack Integration Level 3 with 4 - 9 servers or storage enclosures
232539-888
Factory Express Rack Integration Level 3 with 10 or more servers or storage enclosures
325735-888
NOTE: Includes Level 1 Customer Intent for standard mounted servers and storage units plus standard cable mgmt, RAID configuration, servers & storage, power distribution, networking gear and accessories (price/rack). 
Factory Express Rack Integration Level 4 with 1 - 3 servers or storage enclosures
325734-888
Factory Express Rack Integration Level 4 with 4 - 9 servers or storage enclosures
232540-888
Factory Express Rack Integration Level 4 with 10 or more servers or storage enclosures
325733-888
NOTE: Includes Level 2 Customer Intent plus customer defined cable management and naming convention, customer furnished image download, IP addressing, cluster configurations (SQL, External storage RAID). Quick restore creation, cd duplication, test reports, real-time reporting of server MAC address, password, RILOE). Customer access and validation through VPN (price/rack). 
Factory Express Rack Integration Level 5 with 1 - 3 servers or storage enclosures
325732-888
Factory Express Rack Integration Level 5 with 4 - 9 servers or storage enclosures
232541-888
Factory Express Rack Integration Level 5 with 10 or more servers or storage enclosures
325731-888
NOTE: Includes Level 4 Customer Intent plus Custom SW layering and extended test, Customer access, validation and control through VPN, Clustered racks with networking gear and / or external storage array, Start-up installation services custom quote. (price/rack).
NOTE: Factory Express Engineered Solution Level 6 is a custom solutions available through Factory Express. Please contact your local reseller or Account Manager.

Service and Support Offerings (HP Care Pack Services)

Hardware Services 4-Hour On-site Service  
4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years
U4544A
4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic
U4544E
4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years
U4545A
4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic
U4545E
Installation & Start-up Services  
Hardware Installation
U4554A
Hardware Installation, Electronic
U4554E
Installation & Start-Up of a ProLiant server and Microsoft or Linux O/S per the Customer Description and/or Data Sheet. To be delivered on a scheduled basis 8am-5pm, M-F, excl. HP holidays.
U4555A
Installation & Start-Up of a ProLiant server and Microsoft or Linux O/S per the Customer Description and/or Data Sheet. To be delivered on a scheduled basis 8am-5pm, M-F, excl. HP holidays, Electronic
U4555E
Support Plus  
Onsite HW support, 8am-9pm, M-F, 4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays.
U4556A
Onsite HW support, 8am-9pm, M-F, 4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays, Electronic
U4556E
Onsite HW support, 8am-9pm, M-F, 4hr response and Linux O/S SW Tech support offsite, onsite at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays
U4558A
Onsite HW support, 8am-9pm, M-F, 4hr response and Linux O/S SW Tech support offsite, onsite at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays, Elecctronic
U4558E
Support Plus 24  
Onsite HW support 24x7, 4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays.
U4557A
Onsite HW support 24x7, 4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic
U4557E
Onsite HW support 24x7, 4hr response and Linux O/S SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays.
U4559A
Onsite HW support 24x7, 4hr response and Linux O/S SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic
U4559E
HP Care Pack Priority Services for ProLiant Servers - Priority Silver
NOTE: For more information, customer/resellers can contact http://www.hp.com/services/carepack.
contents
 Overview      Standard Features      Models      Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Memory

HP ProLiant Model DL380 Generation 3 (G3)
Standard Memory

1 GB PC2100 Registered DDR SDRAM DIMM Memory running at 200MHz or 266MHz comes installed (2 x 512-MB SDRAM)
NOTE: Early models (2.4GHz and 2.8GHz 400MHz Front Side Bus) shipped standard with 512MB of memory, these models are no longer available.

Standard Memory Plus Optional Memory

Up to 9,216-MB memory is available with the optional installation of PC2100 Registered DDR SDRAM DIMM Memory Option Kit
NOTE: 2.4GHz models and some 2.8GHz models support a maximum of 6GB of Memory. See model listings.

Standard Memory Replaced with Optional Memory

Up to 12,288-MB of memory is available with the removal of the standard 512-MB of memory and the optional installation of PC2100 Registered DDR SDRAM DIMM Memory Option Kit
NOTE: 2.4GHz models and some 2.8GHz models support a maximum of 6GB of Memory. See model listings.

NOTE: Chart does not represent all possible configurations.

Memory

Slot

 

1

2

3

4

5

6

Standard

1024MB

512MB

512MB

Empty

Empty

Empty

Empty

Optional

9,216MB

512MB

512MB

2048MB

2048MB

2048MB

2048MB

Maximum12,288MB

2048MB

2048MB

2048MB

2048MB

2048MB

2048MB

NOTE: In the online spare configuration, the ROM automatically configures the last populated back as the spare memory. If only banks A and B are populated, bank B is the spare bank. If banks A, B, and C are populated, bank C is the spare bank, Online spare memory is configured through RBSU.

Following are memory options available from HP:

 
  • 4096MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (2x 2048 MB)
    NOTE: The 4096MB of Advanced ECC PC2100 DDR Memory kit (300682-B21) can only be used in 2.8GHz/533/1MB and 3.06GHz and faster models.
300682-B21
  • 2048-MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (2x1024MB)

300680-B21

  • 1024-MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit 2 x 512MB)

300679-B21

  • 512-MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (2 x 256MB)

300678-B21

 
contents
 Overview      Standard Features      Models      Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Storage

0 - 5 Six 6" Wide Ultra3 SCSI hot plug hard drive bays
A 1.44-MB Diskette Drive
B 24x IDE CD-ROM (Universal Media Bay)
C Six 1" Wide Ultra3/Ultra320 SCSI hot plug hard drives or for five hot plug hard drives and one DAT 40 or DAT 72 hot plug tape drive
Drive Support

Removable Media
  Quantity
Supported
Position
Supported

Controller
1.44-MB Diskette Drive 1 A Integrated
IDE CD-ROM Drive1BIntegrated IDE
Slimline DVD-ROM (8x24x) Option Kit (Servers) 1 B Integrated IDE

Hard Drives
Ultra320 Hot Pluggable Drives
 

Quantity
Supported

Position
Supported


Controller

1-inch

Up to 6

0-5

Smart Array 5i Controller (integrated on system board)

300-GB 10,000 rpm
146.8-GB 10,000 rpm
72.8-GB 10,000 rpm
72.8-GB 15,000 rpm
36.4-GB 15,000 rpm

 

 

Smart Array 5304/256 Controller
Smart Array 6402/128 Controller
Smart Array 6404/256 Controller
Smart Array 641 Controller
Smart Array 642 Controller
NOTE: All U320 Universal Hard Drives are backward compatible to U2 or U3 speeds. U320 drives require an optional U320 Smart Array Controller to support U320 transfer rates.

External Storage
  Quantity
Supported
Position
Supported

Host Controller or Adapter
Modular Smart Array 30 Family Up to 13 External Smart Array 5304/256 Controller
Smart Array 6402/128 Controller
Smart Array 6404/256 Controller
Smart Array 642 Controller
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter,
Alternate OS
Modular Smart Array 500 G2 System
1 External Please see the Modular Smart Array 500 G2 QuickSpecs for the latest list of supported HBAs: http://www.hp.com/go/msa500
Modular Smart Array 1000 Please see the Modular Smart Array 1000 QuickSpecs below to determine configuration requirements External Please see the Modular Smart Array 1000 QuickSpecs (URL below) for the latest list of supported HBAs
Modular Smart Array 1500 cs Please see the Modular Smart Array 1500 cs QuickSpecs below to determine configuration requirements External Please see the Modular Smart Array 1500 cs QuickSpecs (URL below) for the latest list of supported HBAs
Modular Smart Array 1000: http://h18000.www1.hp.com/products/quickspecs/11033_na/11033_na.html
Modular Smart Array 1500: http://www.hp.com/go/MSA1500cs

Maximum Storage Capacity – (Enclosure SCSI Attached)
Internal 1.80 TB (6 x 300 GB Ultra320 1")
External 54.60 TB (13 x (14 x 300 GB Ultra320 1"))
Total 58.20 TB

Tape Drives

NOTE: For an up-to-date listing of the latest O/S Support details for each of the Tape Drives listed below, please see the following:
http://h18000.www1.hp.com/products/quickspecs/north_america/10233.html

NOTE: For an up-to-date listing of the latest O/S Support details for each of the Tape Autoloaders and Tape Libraries listed below, please see the following:
http://h18000.www1.hp.com/products/quickspecs/north_america/10809.html

NOTE: For complete listing of tape drive offerings see http://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html

  Quantity
Supported
Position
Supported

Controller
  HP StorageWorks DAT 40 Tape Drive, Internal Hot-Plug
HP StorageWorks DAT 72 Tape Drive, Internal Hot-Plug
Up to 2 0+1, 2+3, 4+5, or 5+C Smart Array 5i Plus Controller (integrated on system board)
Smart Array 5304/256 Controller
Smart Array 6402/128 Controller
Smart Array 6404/256 Controller
Smart Array 642 Controller
Smart Array 641 Controller
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
Ultrium 215, External
Ultrium 230, External
Ultrium 460, External
Up to 2 External 64-Bit/133Mhz Dual Channel Ultra320 SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
       
HP StorageWorks DAT 72 Tape Drive, External
HP StorageWorks DAT 40 Tape Drive, External
HP StorageWorks DAT 24 Tape Drive, External
Up to 2 External 64-Bit/133Mhz Dual Channel Ultra320 SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
       
HP StorageWorks DLT VS80 Tape Drive, External Up to 2 External 64-Bit/133Mhz Dual Channel Ultra320 SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
       
HP StorageWorks SDLT 320 Tape Drive, External Up to 2 External 64-Bit/133Mhz Dual Channel Ultra320 SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
       
HP StorageWorks DAT 72x6 Tape Autoloader, External
HP StorageWorks DAT 40x6 Tape Autoloader, External
1/8 Ultrium 460 Tape Autoloader
1/8 SDLT 320 Tape Autoloader
1/8 Ultrium 230 Tape Autoloader
1/8 DLT VS80 Tape Autoloader
SSL1016 Ultrium 460 Tape Autoloader
SSL1016 SDLT 320 Tape Autoloader
SSL1016 DLT1 Tape Autoloader
1 autoloader per SCSI channel External 64-Bit/133Mhz Dual Channel Ultra320 SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
       
MSL6000 (Ultrium 460 -based) Tape Library
MSL5026S2 (SDLT 320-based) Tape Library
MSL5052S2 (SDLT 320-based) Tape Library
MSL5030 (Ultrium 230 -based) Tape Library
MSL5060 (Ultrium 230 -based) Tape Library
Please reference the MSL Tape Library QuickSpecs to determine configuration requirements External 64-Bit/133Mhz Dual Channel Ultra320 SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
       
ESL712e
ESL630e
ESL9322 ETLA
ESL9595 ETLA
Please reference the ESL e-series & ESL9000 Series Tape Libraries QuickSpecs to determine configuration requirements External 64-Bit/133Mhz Dual Channel Ultra320 SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
contents
 Overview      Standard Features      Models      Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Power Specifications

Part Number 194989-001
Spare Kit 199382-B21
Operational Input Voltage Range (V rms) 90 to 264
Frequency Range (Nominal) (Hz)47 to 63 (50/60)
   
Nominal Input Voltage (Vrms)
100
115
208
220
230
240
Max Rated Output Wattage Rating
400
400
400
400
400
400
Nominal Input Current (A rms)
5.8
5.0
2.7
2.5
2.4
2.3
Max Rated Input Wattage Rating (Watts)
571
563
548
541
541
541
Max. Rated VA (Volt-Amp)
583
575
559
552
552
552
Efficiency (%)
70
71
73
74
74
74
Power Factor
0.98
0.98
0.98
0.98
0.98
0.98
Leakage Current (mA)
0.31
0.36
0.65
0.69
0.72
0.75
Maximum Inrush Current (A peak)
50
50
50
50
50
50
Maximum Inrush Current duration
20
20
20
20
20
20
 
System Specifications

ProLiant DL380 Generation 3 Fully Configured

Up to 2 Processors, 6 Memory Slots, 6 Hard Drives, 3 PCI Slots, and 2 Hot Plug Power Supplies
 
Nominal Input Voltage (Vrms)
100
115
208
220
230
240
Fully Loaded System Input Wattage (W)
431
411
406
400
395
390
Fully Loaded System Input Current (A rms)
4.3
3.6
2.0
1.9
1.8
1.7
Fully Loaded System Thermal (BTU- Hr)
1421
1401
1383
1365
1347
1330

Fully Loaded System VA (Volt-Amp)

425
419
414
408
403
398

System Leakage with all power supplies loaded (mA)

0.63
0.72
1.30
1.38
1.44
1.50

System Inrush Current with all power supplies loaded (A)

100
100
100
100
100
100

Power cord requirements

Nema 5-15P to IEC320-C13
Option no./Spare no.: See Chart below
 IEC320-C13 to IEC320-C14Option no./Spare no.:
142259-001/142258-B21

NOTES:
* To review typical system power ratings use the Active Answers Power Calculator which is available via the online tool located at URL: http://h30099.www3.hp.com/configurator/powercalcs.asp.

To drill down to calculators:
-  Click on: "ProLiant Servers"
-  Click on the Server of interest. Example: DL380 G3
-  Click on: "Power Calculator" link. (You may need to scroll down to see it.)

 
Power Cords (Nema 5-15P to IEC320-C13)
 
Standard Power Cord Part Number/Option Power Cord Part Number
163719-002/227099-001

Power Cords (IEC320-C13 to IEC320-C14)

 

Standard Power Cord Part Number/Option Power Cord Part Number

142263-003/142257-003
contents
 Overview      Standard Features      Models      Options      Memory      Storage      Power Specifications      Technical Specifications line.gif (50 bytes)

Technical Specifications

System Unit

Dimensions (HxWxD)

3.38 x 17.50 x 25.75 in (8.59 x 44.45 x 65.41 cm)

Weight

Maximum:

60 lb (27.22 kg)

 

No drives: 47.18 lb (20.41 kg)

Input Requirements (per power supply)

Range Line Voltage

90 to 132 VAC/180 to 265 VAC

Nominal LineVoltage

100 to 120 VAC/220 to 240 VAC

  Rated Input Current 6A (110V) to 3A (220V)
  Rated Input Frequency 50 to 60 Hz
  Rated Input Power 600W

BTU Rating

1,475 BTU/HR  

SCSI Connectors

One external VHDCI connector
Power Supply
Output Power

(per power supply)
Rated Steady-State Power 400W
Maximum Peak Power 400W
Temperature Range Operating 50° to 95° F (10° to 35° C)
Shipping -40° to 158° F (-40° to 70° C)

Relative Humidity
(non-condensing)

Operating 10% to 90%
Shipping 5% to 95%

Maximum Wet Bulb Temperature

82.4° F (28° C)  

Acoustic Noise

Idle Minimum (Fixed Disk Drives Spinning)
    L WAd (BELS) 7.2
    L pAm (dBA) 56
  Operating Minimum (Random Seeks to Fixed Disks)
    L WAd (BELS) 7.3
    L pAm (dBA) 57

Integrated Smart Array 5i Plus Controller Data Compatible with all Smart Array Controllers Yes
Instant Upgrades to other Smart Array Controllers Yes
Consistent Software Manageability Tools Yes
PCI-X Bus 64-bit, 100 MHz (integrated on system board)
PCI-X Peak Data
Transfer Rate
800 MB/s
SCSI Protocols Supported Ultra3, Ultra2
SCSI Peak Data
Transfer Rate
160 MB/s per channel
NOTE: For ProLiant servers having TWO internal drive bays on separate SCSI ports: SCSI Peak Data Transfer Rate is 320 MB/s total; 160 MB/s per channel and Channels is 2.
Channels 2
NOTE: For ProLiant servers having two internal drive bays on separate SCSI ports: SCSI Peak Data Transfer Rate is 320 MB/s total; 160 MB/s per channel and Channels is 2.
SCSI Ports
(external/internal)
0/2
NOTE: For ProLiant servers having two internal drive bays on separate SCSI ports: SCSI Peak Data Transfer Rate is 320 MB/s total; 160 MB/s per channel and Channels is 2.
Drives Supported
(maximum)
Maximum = total number of drives
NOTE: Maximum is the total number of internal drives on each specific ProLiant server.
Cache 64 MB Read and/or Write Cache
Battery-Backed Write Cache Yes, with installation of Battery-Backed Write Cache Enabler, up to 64MB
RAID Support 0, 1, 1+0, 5
Logical Drives
(maximum)
Maximum = total number of drives
Online Configuration Yes
Online Capacity Expansion Yes
Logical Drive Capacity Extension Yes
Online Stripe Size Migration Yes
Online RAID Level Migration Yes
Online Spare Support Yes
Automatic Data Recovery Yes
Drive Roaming Yes
Redundant Controllers No

NC7781 PCI-X Gigabit NIC (embedded)
10/100/1000 WOL
(Wake On LAN)

Network Interface10Base-T/100Base-TX/1000 BaseTX
Compatibility IEEE 802.3/802.3u compliant

Data Transfer Method

64-bit bus-master PCI-X

Network Transfer Rate

10Base-T (Half-Duplex),

10 Mb/s

10Base-T (Full-Duplex)

20 Mb/s

100Base-TX (Half-Duplex)

100 Mb/s

100Base-TX (Full-Duplex)200 Mb/s
1000Base-TX (Half-Duplex)1000 Mb/s

1000Base-TX (Full-Duplex)

2000 Mb/s

Connector

RJ-45

 

Cable Support

10Base-T

Categories 3, 4 or 5 UTP;
up to 328 ft (100 m)

100Base-TX

Category 5 UTP; up to 328 ft (100 m)

1000BaseTXCategory 5 UTP; up to 328 ft (100 m)

© Copyright 2004 Hewlett-Packard Development Company, L.P.

The information contained herein is subject to change without notice.

Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel Corporation.

The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.


   DA-11473 - U.S. - Version 46 - December 13, 2004 --- Retired on January 31, 2005